Intravane Fixed Displacement Vane Pumps

IVP(Q/V) Model Code - Double Pumps

F3- IVP (Q/V)21 -17 H -12 H A M -F -R -86 AA -10
Prefix, Fluid Compatibility Frame Size Geometric Displacement
●Code
Pressure type
Geometric displ. cover end pump
●Code
Pressure type
Port connections Port connections
modifier
Mounting Form Shaft Rotation ▲Shaft model Port orientation Design
Str. key HD Str. key Splined key
Omit:
Using Petroleum Base oil & anti-wear hydraulic oil

F11-
Using water glycol fluid.

F3-
Using water-in-oil emulsions or phosphate ester fluid.
IVP(Q/V)21 10, 12, 14, 15, 17, 19, 21, 25

 

2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 14

 

 

 


Viewed from shaft end of pump

1 86 11 Viewed from cover end of pump
With no.1 outlet opposite inlet

AA-
No.2 outlet 135˚CCW from inlet
( NO.2 outlet opposite inlet )

AB-
NO.2 outlet 45˚CCW from inlet
( NO.2 outlet 90˚CCW from inlet)

AC-
No.2 outlet 45˚CW from inlet
( No.2 outlet inline with inlet )

AD-
No.2 outlet 135˚CW from inlet
( No.2 outlet 90˚CW from inlet )

With no.1 outlet 90˚CCW from inlet

BA-
No.2 outlet 135˚CCW from inlet
( NO.2 outlet opposite inlet )

BB-
NO.2 outlet 45˚CCW from inlet
( NO.2 outlet 90˚CCW from inlet)

BC-
No.2 outlet 45˚CW from inlet
( No.2 outlet inline with inlet )

BD-
No.2 outlet 135˚CW from inlet
( No.2 outlet 90˚CW from inlet )

With no.1 outlet inline with inlet

CA-
No.2 outlet 135˚CCW from inlet
( NO.2 outlet opposite inlet )

CB-
NO.2 outlet 45˚CCW from inlet
( NO.2 outlet 90˚CCW from inlet)

CC-
No.2 outlet 45˚CW from inlet
( No.2 outlet inline with inlet )

CD-
No.2 outlet 135˚CW from inlet
( No.2 outlet 90˚CW from inlet )

With no.1 outlet 90˚CW from inlet

DA-
No.2 outlet 135˚CCW from inlet
( NO.2 outlet opposite inlet )

DB-
NO.2 outlet 45˚CCW from inlet
( NO.2 outlet 90˚CCW from inlet)

DC-
No.2 outlet 45˚CW from inlet
( No.2 outlet inline with inlet )

DD-
No.2 outlet 135˚CW from inlet
( No.2 outlet 90˚CW from inlet )

10
IVP(Q/V)31 17, 21, 25, 30, 32, 35, 38, 42

Omit
Standard pressure

2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 14

Omit
Standard pressure

A-
SAE 4 bolt flange

M-
Metric
(4-bolt flange)

F-
Flange
mounting
R-
Right hand for clockwise
1 86 11
IVP(Q/V)32 17, 21, 25, 30, 32, 35, 38, 42 H-
High pressure
10, 12, 14, 15, 17, 19, 21, 25 H-
High pressure
 
Omit - Inch
(4-bolt flange)
L-
Foot
mounting
L-
Left hand for counter-clockwise
1 86 11
IVP(Q/V)41 30, 35, 38, 42, 50, 60, 67, 75   2, 3, 4, 5, 6, 7, 8, 10, 11, 12, 14           1 86 11
IVP(Q/V)42 30, 35, 38, 42, 50, 60, 67, 75   10, 12, 14, 15, 17, 19, 21, 25           1 86 11
IVP(Q/V)43 30, 35, 38, 42, 50, 60, 67, 75   17, 21, 25, 30, 32, 35, 38, 42           1 86 11
                       

● Rated capacity in US gpm at 1200r/min and 6.9bar(100psi).
IVPQ series no H high pressure type.
IVPQ series no splined Shaft model.